hiclover

incinerator manufacturer in china

1. Is the residence time over 2 seconds? 3. Could it be supplied as a continuous system? 4. Does it provide for control interventions to adjust waste feed, grate speed, and temperature, quantity and distribution of primary and secondary air? Mode of Heating: Heating Elements of primary and secondary air? 6. Does it include system…

Read More

waste incinerator manufacturer in china

Burning rate: 250 Kg/hr. It should be able to Operate not Less than 10 hours/day This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc… Design Specification: Types A, B, C, D, and E of medical waste “PYROLYTIC” combustion, by controlling the gasification of waste. The incinerator…

Read More

TECHNICAL INCINERATORS SPECIFICATIONS FOR 2 hospitals in Kenya

TECHNICAL INCINERATORS SPECIFICATIONS FOR 2 hospitals   All the incinerators to be supplied and installed must meet the Government of Kenya waste Management Regulation 2006 in particular 3rdschedule regulation (26, 47) pertaining classification, standards, criteria, and procedure for installing/operating incinerators as authored by the National Environmental Management and Coordination (waste management) regulation 2006, legal notice…

Read More

00 BEDS HOSPITAL INCENERATOR TECHNICAL INFORMATIONS

1) Policy – Waste disposal management shall be taken special note to reduce hospital infection. – Infections wastes shall be handled, stored strictly and burnt by a incinerator found at hospital site.   2) Waste Disposal Plan a)Classification – Medical wastes in hospital are classified as follows;   Infections Waste Specially-controlled waste Organ, needle, etc. Industrial waste…

Read More

incinerator manufacturer

“PYROLYTIC” combustion, by controlling the gasification of waste The incinerator manufacturer must prevent the discharge of black smoke and dust that is fine, during the loadings. It shall have the ability to decrease the quantity of wastes by 98%. It shall have the ability to hold emission in the next burn with gas residence of…

Read More

pet incinerator

The incinerator plant shall incorporate a control panel for its operation. On the control panel we shall have a visual screen of the chamber temperatures. This visual display must control and monitor the incinerator along with his performance. Ability of destruction in weight shall be 60 Kg/h. It should be able to operate not less…

Read More

mobile incinerator

Petrol: diesel   Consumption: 8-10liter/hour   Capacity: to cremate (carrion and spoils) 350-400kg/hour   Temperature: 900-1350?C   Operation temperature: -30~40?C   Incinerator weight: 1800-2000 kg   Volume: 0.70-0.80m/cube   Exterior dimension: 1.4-1.6*1.0-1.15m (L*W) An incinerator represents a comprehensive solution to the problem of disposal of all hospital waste types. The liquid gas is petrol. The…

Read More

Wastes That Can be Burned or Incinerated

Complete combustion converts waste into inert bottom ash with minimal production of smoke, fly ash and toxic gases. Several factors influence this process including the heating value, wetness and chemical makeup of the waste itself, operating conditions in the burn chamber (i.e. temperature, holding time and turbulence) and operator skill. The method used is important…

Read More

hospital incinerator

NB.: Civil works and some other relevant services for the installation and training of operators must be included in the incinerator’s cost. 22. Process Filtering system: Scruber to be mentionned as discretionary 23. 25. The technical training of operators will have to be supplied and given by a technician from Specification for the shelter of…

Read More

medical incinerators

18.     A room of post combustion of gases * A burner of combustion of gases, ?     ?     Nature: 65% of Al203 * A device of air inlet of cooling of waste gases, ?     . Nature: 42 percent of Al203 ?     * Carcass in solid sheet steel with support of connection….

Read More

hospital incinerator design

d’inspection 7)Volume chambre postcombustion                                                                   2.1 m3 Est dimensionnée pour pouvoir  garantir  un temps de fumée de 2 secondes à 1100°C avec un pourcentage d’oxygène libre d’au moins 6%. ? Soupape de régulation de l’air motorisé selon les stages de cycle de fonctionnement et de la température 5. CHAMBRE DE POST COMBUSTION ? Affichage des  températures …

Read More

Medical incinerator primary combustion price

environment contract management firm with planned operations 2013 in Indonesia and Thailand, and 2014 in West & East Malaysia to execute those professional services in order to abide by the governments safety disposal requirements for hospital and medical, clinical waste in the region and to meet the higher technical standard in this particular field.small incinerators…

Read More

small capacity incinerators

7.     A 99.99% destruction and removal efficiency (DRE) for each principal organic hazardous constituent (POHC) in the waste feed where: DRE = [(Win – Wout)/Win]*100 2.     If the minimum combustion temperatures aren’t maintained. Arsenic                                       As Barium                                        Ba 5.     All the emission to the air apart from steam or water vapour has to…

Read More

china medical incinerator

china medical incinerator Ability ? Typical Daily Max/Min January Temperature, 2-12°C. ? Disposal of both non-hazardous and hazardous waste streams (per waste inventory) Design/Specifications ? Average Daily Max/Min June Temperature, 21-39°C ? The incinerators will be installed with visual alarms to alert operations of reduced temperature in the secondary chamber diesel fuel / mains power…

Read More

cheap incinerators

Temperature Controlled Burner. Incinerators to be designed to meet the Norms of Pollution Control. Technology: Heavy-duty casing, to be a quality, rugged, dependable, economical Incinerator with relevant control, easy to operate and self-contained. Units to be pre-assembled, pre-piped, pre-wired & tested before Transfer / Export. Note: Similar Technology and / or Tenderers Proposals are welcome….

Read More

Waste Incineration HICLOVER Model TS75

Waste Incineration HICLOVER Model TS75  Items/Model TS75(PLC) Picture Principle Waste Incineration Burn Rate Average 75 kg/hour Feed Capacity Average 150kg Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 770L Internal Dimensions 100x81x95cm Secondary Chamber 385L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.7Kw Oil Consumption (kg/hour) Average 16.9 Gas Consumption (m3/hour) ***…

Read More

medical waste incinerator china

medical waste incinerator china, Design, supply and Fabrication ex works of a Single Surefire Manual Load TS50/1 Medical/General waste incinerator as detailed below: – ·         Waste type: Mixed Form o,1,2,3,&4 hospital/clinical bio hazard waste ·         Waste density: 125 to 350Kg/M3 ·         Waste CV: 4000 KCAL/kg ·         Moisture content: 10-25Percent ·         Estimated ash residue: 5-10Percent ·        …

Read More

Medical Waste Incinerator HICLOVER TS10 PLC 10kgs per hour

medical waste incinerator iraq price HICLOVER TS10 PLC 10kgs per hour Items/Model TS10(PLC) Picture   Burn Rate Average 10 kg/hour Feed Capacity Average 20kg/feeding Control Mode Programmable Logic Controller(PLC) Panel Combustion Chamber 100L Internal Dimensions 50x50x40cm Secondary Chamber 50L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.5Kw Oil Consumption (kg/hour) Typical 8.4kg/hour Gas…

Read More

Automated PLC controller incinerator plant with Dual heat burners and dual chamber HICLOVER YD-30C with Wet Scrubber

Item Specification Model YD-30C Main Product List Main Combustion Chamber(Main body stainless steel) Secondary Combustion Chamber(Main body stainless steel) Mix-Combustion Chamber Wet Scrubber( Washing Tower)(Main body stainless steel) Incinerator Control Case Chimney:5.0Meters *(Update to Stainless Steel, free cost) Italy gas burner: 02 sets Oil Tank (if oil fuel): 100Liters Automatic PLC controller incinerator plant with…

Read More

chinese incinerator manufacturers

In a simple design with a metal steel drum electric. including: Ancillaries High temperature painting for several of the incinerator. A combustion chamber with fireplace using a filter to retain ashes; Weight    1850kgs Supply of incinerator model PDR-18 with: ·        Ability 100 kg/hr of waste containing up to 85% moisture ?      With 2 diesel pipelines,…

Read More

Large Capacity Animal Pet Cremation HICLOVER Model A1500 with E-Power Auto.Door

Large Capacity Animal Pet Cremation HICLOVER Model A1500 with E-Power Auto. Door Model A1500 Internal Dimensions 150 x 100 x 96cm Suit for Animal Cat – yes Dog – yes Pig – small Cow – small Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber Smoke Filter Chamber Incinerator Control Case Chimney:10.0Meters *(Update to…

Read More

hospital incinerator manufacturers

hospital incinerator manufacturers, Waste streams of petrochemical unit collect and store in Transit and Sorting Center. –    Materials (wastes) that need to be stabilized before buried –    Buried materials The Incinerator Plant is output wastes incineration from various petrochemical units. In this project we want to incinerate all output wastes from petrochemical units and produced…

Read More

Waste Incineration Treatment BURNING RATE : 100-150kgs per hour HICLOVER TS150

BURNING RATE: -100-150kgs per hour MINIMUM OPERATING TEMPERATURE: 800-1000 oC ( PRIMARY COMBUSTION ) MAX OPERATING TEMPERATURE: 1000-1200 oC ( AFTER BURNER COMBUSTION ) SECONDARY BURNING CAPACITY: COMPULSORY DENSITY INSULATION: 50 mm high Refractory capacity: min 114mm HEAVY DUTY REFRACTING LINING TO WITHSATND 17500C AVEARGE BURN OUT TIME: MAXIMUM 3HRS FUEL TYPE: FUEL OIL (…

Read More

Pet Crematory HICLOVER A600

Model A600, crematorium manufacturers Internal Dimensions 130 x 70 x 65cm Suit for Animal Cat – yes Dog – yes Pig – no Cow – no Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber Smoke Filter Chamber Incinerator Control Case Chimney:5.0Meters *(upgrade to Stainless Steel, free cost) Italy oil/gas burner: 02 Components…

Read More

Incinerator with 1 or 3 section type wet scrubber

Medical waste is currently managed via an old medical waste incinerator; which also manages the associated medical waste delivery and ash removal arrangements.Pathological waste: organs, tissues, surgical specimens, bodily fluids removed during surgery or autopsy.  Mix and moisture content not known.Allow for weekly deliveries @ 8 hour per day operation = 11 kg per hour…

Read More

Waste incinerator producers from china

Incinerate: medical waste and general waste Capability to burn waste: ·         Use: For medications ·         With Chassis to be Mounted in truck/lorry ·         May have a primary and secondary combustion chamber ·         Must have a dilution chamber ·         Ability: 100 Kgs per hour

Read More

DIESEL FIRED INCINERATOR, WITH 1000 LTR FUEL TANK AND 6M CHIMNEY

Items/Model TS250(PLC) Picture Principle Waste Incineration Treatment Burn Rate Average 250 kg/hour Feed Capacity Average 400kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 2000L Internal Dimensions 210x88x110cm Secondary Chamber 1000L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 2.0Kw Oil Consumption (kg/hour) Typical 24.2(DO) Gas Consumption (m3/hour) *** Temperature Monitor Digital Display…

Read More

incinerator for medical waste

1. GENERAL SPECIFICATIONS: The incinerator for medical waste needs to be designated for the destruction of all kinds of waste produced by the Center for Health (waste type hospital, clinic, medical laboratory for destructive capacity of 30kg / h). Avoid development of black smoke and dust formation tine loading of waste; . Afterburner ? 1…

Read More

Incinerator Parts Mineral Insulated Thermo couple Detector K-Type 300SS

Incinerator Parts Mineral Insulated Thermo couple sensor K-Type 300SS K type 300SS: M27*2, 300mm Ins,2520 S.S, 2.5mm core  HICLOVER – Medical Environmental    WWW.HICLOVER.COM Waste Incinerators Medical Waste Incinerator Pet Animal Cremation Solid Waste Incinerator Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.vip.hiclover.com  Email: [email protected]Email: [email protected]   Nanjing Clover Medical Technology Co.,Ltd.   smart

Read More

Small scale clinical waste incinerator

Toxic and Harmful wastes, Combustion supporting materials Oil Industrial wastes 35.64 small scale medical waste incinerator Prerequisites <78dB Index of let smoke and waste gas Medical Incinerator, 24 kg/hr including panel board, controls and accessories Guide Medical Incinerator, 24 kg/hr 200 beds Input Fashion Domestic garbage Chimney 0.016 800-10000C 1000-12000C Burning efficiency Gas Medical Incinerator,…

Read More

50kgs/hr iraq general waste incinerator with Two combustion chambers

Items/Model TS50M Picture   Burn Rate Typical 50 kg/hour Feed Capacity Typical 50-150 per feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 450L Internal Dimensions 75x75x80cm Secondary Chamber 225L Smoke Filter Chamber Yes Feed Mode Manual Feeding Voltage 220V Power 0.5Kw Oil Consumption (kg/hour) Typical 13.3 Gas Consumption (N.G, m3n/Hour) Typical 16 Gas Consumption…

Read More

medical waste incinerator for sale

Waste type: health care waste It is carried from the floor level on a considerable steel support frame.  Internally the shell is lined with calcium silicate insulation and a hot face combination of super duty brickwork or higher strength castable. The primary combustion chamber must ensure minimum exit temp is not less than 850? C….

Read More

Incinerator with Movable platform & Automobile.Door and Design for Pets Human Cremation Business

Design for Pets Cremation Business Movable platform & Auto. Independent Position for Small Pet Incinerator with Movable platform & Auto. Door and Design for Pets Human Cremation Business Model A1500 Picture Burning Rate Average 150 kgs/hour Feed Capacity Average 350 kgs/feeding Primary Combustion Chamber 1500 Liters Secondary Combustion Chamber 500 Liters Mix Combustion Chamber Yes Smoke…

Read More

Smallest Incinerator 30kgs

Average 30kgs per hour ***Main chamber(200Liters) *** Secondary chamber *** Mix combustion chamber *** Stainless Steel chimney(1meter) *** Italy made oil burner(2sets) *** Dry Scrubber *** Weight 1.7T(can reduce to 1.0Ton) Main Spare Parts(Standard for incinerator, and price Comprise already): *** 2 sets Italy Oil Burner *** 2sets Temperature Probe *** 1 set Control Case…

Read More

incinerator manufacturers

d) A smoke density meter/recorder should be provided. G) The average dioxin and furan concentration in the emission should not exceed 80mg/m3 total dioxins and furans if measured for a period of 6 to 16 hours. – Manual technical monitoring is shipped with the hardware together with all explanations of failures and resolutions B) The…

Read More

Melt blown Production Line 400mm and 1600mm and ES Fiber Production Line and N95 Mask Machine and Disposable Mask Machine

1. 400mm and 1600mm Melt blown Production Line 3. ES Fiber Production Line       N95 Face Mask Machine Production Line Melt blown Production Line   A.)Optional Ability: 1600mm Efficiency: 95-97percent FOB Term Cost: USD per set Price Valid: 5days. Ave.60 Days prepared for shipping. In stock Price: USD per set     B.)Optional…

Read More

medical incinerator manufacturer

9. Metal fuel tank from black steel (capacity not less than 2500 litres) and will be installed in the incinerator Room. The tank shall be supplied with all necessary fittings such as fill, vent, drain and overflow line, level indication and accessibility for inspection and maintenance. Level switches shall be provided for these services. –…

Read More

laboratory incinerator

the Whole carcass of animals ( Horses, Cows, air retention for at least 2 seconds at a temperature of less than 850C, the combustion C to – 15 0C laboratory incinerator Temperature and 5% – 95 percent – of moisture conditions. Which are managed remotely by the operator. ? Fully mobile – mounted on wheeled…

Read More

Medical Incinerator Manufacturers in Stock ready for Transport

Medical Waste Incinerators in Stock. Twitter: https://twitter.com/hiclovercom Phone/WhatsApp/Wechat: +8613813931455, Web: www.vip.hiclover.com Web: www.clover-incinerator.com Double Combustion Chamber,Double Italy Burner,Smoke Filter Included,Burning Rate: 50-200kgs per hour optional,Primary Combustion Chamber: 1.57M3(1570Liters),Incinerator Mainbody steel: 8mm thickness,Paint for outside face: 800°C Rate,Chamber Material: High Alumina Fire Brick Wall, 1750℃ Rate,Idea for campsite average or below 600 people,Chimney: 10 Meters, Stainless…

Read More

medical incinerators

● Willing to burn 25-30kg per hour 2 sec. 1000×1670 -Stainless steel stack Width (mm) -Automatic control and temprature 790 ● Need more than 15amp 220- 250V power ·         General wastes produced on a daily basis  include paper, plastic, organic materials, boxes, plastic containers, leaves, etc; ·         Total waste produced daily: 10-12 tonnes; ·         Hours…

Read More