hiclover

Supply, Installation and commissioning of Waste Incineration system

The proposal must include the comprehensive description of the whole system: Total cost of supply, Installation, commissioning, Automatic feeding, automatic de- ashing through performance, and efficient gas cleaning system (wet, dry or higher temperature ceramic filters), continuous emission monitoring system (CEMS), and all    other    accessories, Control    panel    for    all     components     of     the system, Troubleshooting alarm…

Read More

an incinerator for our dental clinics

2. A camera post-combustion gases : Cold filter plugging point -10 ° C max. DIESEL AND FOOD TANK BURNER The fuel tank will be found annexed into the dugout roof incinerator at a bund and have the following characteristics: • Capacity: 1,200 liters • Made of sheet steel for easy wall installation cubeto Point above…

Read More

medical waste materials incinerator

company. Our products main for small waste output. For hospital straight, local at hospital, or portable/mobile incinerator to a single website when end-customer request. incinerator without smoke and smelting for the environment. capapcity 500kg per day. Could you specify the point of petroleum fuel? By this you mean petrol or diesel? an incinerator acceptable for…

Read More

waste disposal incinerator

2. What’s your minimum capacity and maximum capacity incinerator. 3. You do provide secodn hand incinerator in good working condition. Incinerator but the size of room > 2000 x >1200 mm. Prepare for burn LIQUID Waste +/- 20 liter/hr. C: How many batch can we place in each day basis per 24 hours. The chamber…

Read More

Refractory Concrete Incinerator

Disinfecting/sterilizing the contaminated medical wastes, main combustion chamber, post combustion chamber, heat exchanger, ash removal components and flue gas treatment systems, together with the following details: Hourly capacity of the system:           from 250 up to 500 Kgs/ hour Duration of operation:                        from 14 up to 18 hrs/ day Fuel type to be used:                         Diesel or…

Read More

BIO WASTE INCINERATOR

50 kg/  hour  capacity incinerators ·        Burning Rate: 50kos/hr ·        Feed Capacity:  150kqs ·        Main Combustion  Chamber:  900 Dimensions ·        Secondary  Combustion  Chamber:  300 Dimensions ·        Mix Combustion  Chamber:  Yes ·        Smoke Filter Chamber:  Yes ·        Feed Mode: Manual ·        Power: 0.7Kw ·        Fuel Type: Diesel Oil/ Natural Gas/LPG ·        Internal Dimensions:  120 x 90…

Read More

Containerized Mobile Incinerator Medical Waste Incinerator Model CA50

HICLOVER – Containerized Mobile Incinerator Medical Waste Incinerator Model CA50 Model CA50 Picture Waste Treatment Medical Waste Incineration Treatment Feed Capacity Average 100 kgs per feeding Burning Rate Average 50 kgs per hour Burning Time per Feed Average 2 hour Control Mode PLC(Programmable Logic Controller Incinerator) Voltage 220V Power 1.0 Kw Gas Diesel oil Burner Italy…

Read More

Small Medical Waste Incineraotr for COVID-19 Bio Hazardous Medical Waste

HICLOVER – Medical Environmental  Model YD-20 Picture Burning Rate Average 20 kgs/hour Feed Capacity Average 60 kgs/feeding Primary Combustion Chamber 360 Liters Secondary Combustion Chamber 200 Liters Mix Combustion Chamber Yes Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 1.0 Kw Fuel Type Diesel Oil/ Natural Gas/LPG Burner Italy Original Oil Consumption (Diesel…

Read More

Containerized Type Pre-Assembled Mobile Hospital Waste Incinerator Model CA100

Items/Model CA100 Picture Principle Medical Waste Incineration Treatment Burn Rate Average 100 kg/hour Feed Capacity Average 200kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1200L Internal Dimensions 120x100x100cm Secondary Chamber 600L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 1.3 Kw Oil Consumption (kg/hour) Average 20.4 Kgs/Hour Gas Consumption (m3/hour) *** Temperature…

Read More

Three Combustion Chambers MEDICAL WASTE INCINERATOR

Model WS-35 Picture Burning Rate Typical 35 kgs/hour Feed Capacity Typical 80 kgs Primary Combustion Chamber 460 Liters Secondary Combustion Chamber 200 Liters Third Combustion Chamber 200 Liters Smoke Filter Chamber Wet Scrubber System Feed Mode Manual Voltage 220V Power 2Kw Fuel Type Natural Gas/LPG Burner Italy Original Oil Consumption (Diesel Oil) *** Gas Consumption…

Read More

Small Scale Medical Waste Coronovirus (Covid 19) Incinerator 30 kgs per hour Model TS30 PLC Car Control

Items/Model TS30(PLC) Picture   Burn Rate Average 30 kg/hour Feed Capacity Average 60kg per feeding Control Mode PLC(Programmable Logic Controller Incinerator) Car Control and Display Combustion Chamber 330L Internal Dimensions 75x75x60cm Secondary Chamber 180L Smoke Filter Chamber Yes Feed Mode Manual Feeding Voltage 220V Power 0.5Kw Oil Consumption (kg/hour) Average 13.3 Gas Consumption (N.G, m3n/Hour)…

Read More

Incinerator Light Shipping Weight Small-Scale Hospital Medical, Containerized Mobile Incinerator Optional

Light Weight Small-Scale Medical, Mobile Optional Type Related Incinerator A2400 Medical Waste Incinerator N95 Face Mask Machine Production Line on Sale Now! $250,000USD per set HICLOVER Burner mobile little With Wheel as well as Brake www.clover-incinerator.com Rewrite Your Articles! HICLOVER.COM https://www.youtube.com/watch?v=BxiEa3XYvBs Contact Us Incinerator Video https://www.youtube.com/watch?v=CDdacp1wk1A express vpn Waste Incinerators Recent Posts Melt blown Production…

Read More

Incinerators QA

Q: what is kind of waste can use in this equipment?A: This equipment for medical waste, pet animal, Municipal waste, live waste. Prohibit any  explosive and radiation material, liquid waste and gas waste. Q: Remedy capacityA: Average Capacity calculated by medical waste(lower calorific power (L.C.P): 3.0TH Kcal/Kg per hour),  not mean any waste material. The animal/pet combustion rate around 2/3 of average capacity.   Clover incinerator use time daily to 24 hours.  Between each feed/combustion time,  there are about 0.5-1 hours cooling time and time for feeding waste. Actual combustion  time per day is around 16 hours. The lifetime of incinerator between 5-10 year according to use.  Generally, we proposal little lab, little clinic use capability under 20 kgs per hour.  When incinerator use in hospital, please calculate the waste output capacity around 2kgs  per people per day. If there are 200 sickbed in the hospital, that’s mean you need one  incinerator capacity around 400kgs per day, change to capacity per hour is around 30-40 kgs  per hour. According the operation time per day, waste material, budget,  development, etc, you can use capacity from 30-50 kgs per hour incinerator.*How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste. Q: Assembly and TestingA: We provide all documents and incinerators simple to setup and operation.  Customer  can send people come to our factory to learn installation and operation. Generally,  We do not send engineer to local site if not request. The dispatch cost is extra according to order. Q: Combustion TemperatureA: The first combustion chamber: 800-1000 centi degree.The second combustion chamber: 1000-1200 centi level. Q: Incinerator Control ModeA: Default Control mode is common control case.  PLC mode according to order and model. Q: Operation and maintenance costsA: Operation cost according to fuel consumption rate and power/staff, etc.  Annual around $500-$1000usd annually care according model, use scenario.  One individual can service 02 device incinerators.  The team should have basic electrician  knowledge to operate/inspect/maintaince incinerator/burner/blower according to  operation user guider, and know risk of medical waste to protect worker self with necessary protection element. Q: The Residency time in secondary combustion chamber A: 02 sec. WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.vip.hiclover.com  Email: [email protected]Email: [email protected]   Items/Model…

Read More

cytotoxic waste

it’s also very important for us to know whether the unit is qualified to deal with cytotoxic waste and also the characteristics and disposal of treatment residues. Moreover, operational needs in terms of electricity and fuel consumption, as well as especially the off-gas treatment system implemented, bear significant importance, as fulfilling the requirements of Regulation…

Read More

HICLOVER INCINERATORS

Medical waste is posing a growing problem all around the world, jeopardizing the health of staff, patients, disposal employees and anyone else coming into contact with the often hazardous materials discarded by hospitals and other healthcare sites. Hospital waste varies from site to site and the biggest challenge is to dispose of this broad range…

Read More

HIGH TECH PYROLYTIC MEDICAL WASTE INCINERATOR

HIGH TECH PYROLYTIC MEDICAL WASTE INCINERATOR 1.   21. The de- ashing must be performed in the bottom of the combustion chamber or the deashing Electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating * A timer with flexible temporization for the regulation of every burner. * Carcass in solid sheet steel with support…

Read More

Pet Animal Crematory Incineration

Incineration is the most obvious solution for total destruction of municipal waste, avoiding  all the direct and indirect risks associated with other disposal methods.Incineration perfectly fits into a trend of treating waste in a safe way, and if possible, at the  same place where it was generated to avoid cross-contamination risk and to keep waste treatment costs at acceptable level. — Upgrade/Downgrade Burning Rate WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. ※Main Feature:–Three Combustion Chambers or A/B Main Combustion Chamber— Double or Three Italy Burner–Burning Rate: 80-800kgs per hour–Combustion Chamber: 1.0M3-10.0M3※Optional Function/Parts/Material/Burning Rate: — Stainless Steel Chimney — Dry Smoke Filter Chamber— Chimney Height Custom Made— Semi-Automatic Waste Feeding— 3-Section Wet Scrubber System— Movable Platform Feeding Door— Additional Burner Mobile: +86-13813931455(whatsapp/wechat)Website: www.vip.hiclover.com  Email: [email protected]Email: [email protected]   Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg Control Mode PLC PLC PLC PLC PLC Combustion Chamber 100L 210L 330L 560L…

Read More

Capacity of destruction in weight 60 Kg/h

Quantity: Two [2] with complete accessories. Kinds of wastes being used: GENERAL WASTE.Polyester, polypropylene, polystyrene, vinyl acetate plastic, synthetic plastics, – Assumption: general hospital beds 50 percent, surgery beds 50% for the 100 bed hospital instance, while this ratio is 30-70% for the other cases * Frontage of loading door seals gone up on hinges,…

Read More

HICLOVER Made Waste Incinerators

HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection, animal and pet cremation engineering, other municipal solid waste incineration project. We provide single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators for laboratory, clinic, hospital, medical center, hygiene clinical waste destruction with medical disposable, biological waste,…

Read More

Incinerator capable of treating between 300 & 500 kgs fitted Using the wet scrubber system

Automatic loading and reloading with capacity of 10 to 12 tons per day working with gas treatment procedures and gasoline fuel and should comply with the European Standards.the Government Hospital for Medical Waste Incinerator with these Specifications. They’re having general wastes like cells, plastic bottles ,wastes coming from labour camps, to be incinerated, they want,…

Read More

Incinerator factory

Key Features: General Municipal Solid Waste Incinerator, Pet and Animal Cremation,  Containerized Mobile Incinerator, High Efficient Environmental Waste Incinerator.— Single combustion chamber, double combustion chambers, three combustion chambers and  multi-combustion chambers waste incinerators.— System solutions for medical waste environmental.— High burn rate, from 5kgs to 1000kgs per hour.— New Design for pet animal cremation business. — HICLOVER, trusted partner with years of experience. WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. — Full range incinerator with Economized Small Scale incinerator, Standard Small-Large Scale incinerator,  Mobile: +86-13813931455(whatsapp/wechat)Website: www.vip.hiclover.com  Email: [email protected]Email: [email protected]   Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg Control Mode PLC PLC PLC PLC PLC Combustion Chamber 100L 210L 330L 560L…

Read More

Animal body parts,other biomedical waste,organs dung

13.     Civil    works,    installation    and Comnuss!Onmg    lndusive  of  civil  works  (brick  wall  incinerator  house Type of waste for disposal    Animal  body  parts,other  biomedical  waste,organs dung, bedding materials,plant p缸ts and meals itemsι bidding document 51. No    Features    $_pecific tions 6.     11.     Opening lid    Large top open归g lid (Approx. 700 mm x 500mm) for…

Read More

HICLOVER Waste Incinerator Front view

— Full range incinerator with Economized Small Scale incinerator, Standard Small-Large Scale incinerator, General Municipal Solid Waste Incinerator, Pet and Animal Cremation, Containerized Mobile Incinerator, High Efficient Environmental Waste Incinerator. — System solutions for medical waste environmental. — High burn rate, from 5kgs to 1000kgs per hour. — New Design for pet animal cremation business. — HICLOVER, trusted partner with years of experience. Nanjing Clover Medical Technology Co.,Ltd.. Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg Control Mode PLC PLC PLC PLC PLC Combustion Chamber 100L 210L 330L 560L 1200L Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm Secondary…

Read More

Containerized Mobile Incinerators

○ Containerized Mobile Incinerator(CA Model) HICLOVER now offer a full range of containerized incineration systems, placing us at the forefront of the latest transport and industrial trends. Containerization enables immediate waste management as the units are pre-assembled and pre-installed. Containerization is the most feasible and viable option in contrast to the construction of on-site facilities…

Read More

a pet incinerator for the cremation of dogs

We’ve got a 70 bed hospital in namibia. However there is a potential of getting clients from other regional doctors. A tiny incinerators (ex. Please see attached) for a few empty chemical luggage. Can you please provide me with some details information about these type of incinerators (small scale). A pet incinerator for the cremation…

Read More

The three incinerators for burning and incineration of drugs and toxic substances

Requirements and specifications for the process of distribution, installation, operation and guarantee the three incinerators for burning and incineration of drugs and toxic materials for customs department Free three years guarantee for incinerators from delivery date. Along with free spare parts guarantee letter ought to be valid for 10 years from the end date of…

Read More

WASTE INCINERATOR

  –          150 KG/HR –          Compliant with EU rules, Directive 2000/76/EC –          Fuel type: Diesel –          Easy management and maintenance –          Temperatures: 850 deg C for municipal waste 1000 deg C for medical waste 1100 deg C for harmful waste containing halogenated organic substances with content of chlorine or its compounds.

Read More

Medical Waste Incinerator BID

1. Technical specifications; I. Size of the Incinerator 4,410W x 3,037L x 4,836H mm II. Ability of the Incinerator Medical waste 50 kg/hr. Batch feeding (low level caloric value: 4,000 5,000kcal/kg) III. Utility Utility condition for the incineration equipment operating is the following. 1) Gas: Light oil or Kerosene 2) Electricity Motor -0.1 — 110kW:…

Read More

Medical Waste Incinerators

Incinerator but the size of chamber > 2000 x 1200 mm. Prepare for burn LIQUID Waste +/- 20 liter/hr. C: How many batch can we place in each day basis per 24 hours. A;  Batch Capacity for each version, how much load can we place in 1 time. I need tio under stand in duration…

Read More

incinerator plant specification

1)  Electricity Supply: (a) Mains Supply: (I)  Single Stage supply; 220 — 240V, 50Hz (ii) Three Stage supply; 380 — 415V, 50Hz (iii) The power supply outlet (sockets) for single phase distribution system at the hospital is three hooks and conforms to BS1363. (b) Fluctuation: (I)  Mains fluctuation is a frequent problem, the performance should…

Read More

MUNICIPAL SOLID WASTE INCINERATORS

Medical incinerator with a 10 kg/hour (15 lbs/hour) capacity shall be constructed on the site, complete with Stacks, control panels and all accessories, complying with 01015 par. 5.16.2 -Oils MUNICIPAL SOLID WASTE INCINERATORS Municipal waste incinerator quantities and capacities shall be made for 24-hour 7-day-a-week continuous operation. Incinerators will be capable of processing both wet…

Read More

Incinerators

burn between 5000-10000 kg per hour.Mostly waste from crude oil tanks. Construction, installation and 6 weeks maintenance cost including specifications.CMSD for Double Chamber Rotary Klin Type Incinerator (1st Chamber temperatur not less than 850 degree centrigrade & 2nd Chamber Temperature  not less than 1200 c with exhaust pipe 100 meter long with emission gas filtering…

Read More

Incenerator System

Incenerator Supply, installation and testing of medical waste incinerator with a capacity of 75 kilograms / hour, operated by LPG and including all accessories with chimney in accordance with the technical specifications and public health regulations Item 2 Incinerators room for 3 incinerators as item 3-1-1, and waste store for keeping wastes for 7 days,…

Read More

burning hazardous waste and chimicals incinerators

each day, necessary number of units -10 to 25 numbers Installing different sort of waste Management systems preferably Incineration and others for the state Jammu & Kashmir India manufacturer and exporter of various Incinerator and other goods. Please note that we are a leading Bangladeshi business house dealing in various Medical, Surgical, Dental, Hospital goods,…

Read More

medical waste PYROLYTIC INCINERATOR

Parameter Compliance Type of Waste To treat medical waste, categories A,B,C,D,E Type of Incinerator Pyrolytic Nominal Burn rate 50 t0 60 kg/ hr at 3500Kcal/Kg Loading Manual, Batch Load De Ashing Automatic or Manual batch de ashing The incinerator must avoid the release of black smoke and fine dust during the loading Primary chamber capacity…

Read More

Dual Combustion Chamber Containerized Mobile Incinerator Family Pet Dog&Cat Cremation Installation and Commissioning

Double Combustion Chamber All waste incinerator design with double combustion chamber. High Temperature, Smoke Treatment,No black smoke, Environmentally friendly. Containerized Mobile Incinerator The incinerator mounted in ISO Container before depart mill, free-installation, no incineration house build structure,movable by truck. Family Pet Dog&Cat Cremation Special design with movable platform, combustion chamber material and custom made for…

Read More

Waste incineration industry momentum is fierce level of related facilities to be Enhanced

[China] Solid Waste Environmental online waste incineration industries development momentum is fierce, and the cleverest of capital chasing even appear many times in the last year the price of handling fee diving, industry raised concerns about the vicious competition. “Thirteen Five” during garbage construction market investment space at 1000 billion yuan; the growing garbage incineration…

Read More

Waste Management Planning

If burning and incineration is used, the equipment selected ought to be designed and sized to accommodate the waste produced, minimize fire hazard and result in the complete combustion of the waste. The generator of a waste is responsible for its safe management from cradle-to-grave. Using raw materials efficiently and reducing the amount of waste…

Read More

hazardous and biomedical waste

uniform heating value near the design stage of the incinerator. Externally supplied fuel and electricity are necessary for the burners and forced air ventilation. A correctly functioning dual- chamber controlled air system will reduce problems with animal attraction since the production of bottom and fly ash and smoke is minimized. Section 2.3.2 is intended to…

Read More

Smokeless Medical Waste Incinerator HICLOVER Model YD-30M

Model YD-30M Primary Combustion Chamber Secondary Combustion Chamber Mix Combustion Chamber Smoke Filter Chamber Incinerator  Control Case Stainless Steel Chimney: 1.5 Meter Italy oil/gas burner: 02 sets Oil Tank (if oil fuel): 100Liters Video material: https://twitter.com/i/status/1279030799182905345  Model YD-30M  Picture Burning Rate  average 20 kgs/hour Feed Capacity average 40 kgs/feeding Paimary Combustion Chamber 200 Liters Secondary…

Read More

Dual heat burners and Double chamber incinerator Burning capacity up to 30 Kg per hour with wet scrubber

Dual heat burners and dual chamber incinerator Burning capacity up to 30 Kg per hour Main Product List Primary Combustion Chamber(Main body stainless steel) Secondary Combustion Chamber(Main body stainless steel) Mix-Combustion Chamber Wet Scrubber( Washing Tower)(Main body stainless steel) Incinerator Control Case Chimney:5.0Meters  Stainless Steel Italy gas burner: 02 sets Oil Tank (if oil fuel):…

Read More