hiclover

Plus Size Burning Rate : 150-200 kg/hr Strong Waste Devices Main as well as 2nd Combustion Chamber Burner

Items/Model TS500( PLC) Photo Principle Waste Incineration Therapy Melt Rate 150-200 kg/hour Control Setting PLC( Programmable Reasoning Control Heater) Combustion Chamber 2700L Inside Dimensions 190x120x120cm Second Chamber 1300L Smoke Filter Chamber Yes Feed Setting Guide Voltage 220V Oil Intake (kg/hour) Common 28 Gas Use (m3/hour) *** Temperature Show Digital Show Temperature Level Safety And Security…

Read More

Device Measurement : Burning Rate : 60-80 kg/hr Pyrolytic Double Chamber Burner

Items/Model TS100( PLC) Image Concept Waste Incineration Treatment Shed Rate 60-80 kg/hour Control Setting PLC( Programmable Reasoning Controller Burner) Burning Chamber 1200L Inside Measurements 120x100x100cm Second Chamber 600L Smoke Filter Chamber Yes( Dry Scrubber) Feed Establishing Guide Voltage 220V Oil Utilization (kg/hour) Common 20.4 Gas Consumption (m3/hour) *** Temperature Level Monitor Digital Present Temperature Level…

Read More

Pyrolytic Twin Chamber Incinerator Small Size : Burning Rate : 30-45 kg/hr ; Optimum Loads Ability : 400 kg

Items/Model TS50( PLC) Image Principle Strong Waste Incineration Burn Price 30-45 kg/hour Control Mode PLC( Programmable Reasoning Control Heater) Burning Chamber 560L Inner Measurements 100x80x70cm Secondary Chamber 280L Smoke Filter Chamber Yes Feed Establishing Manual Voltage 220V Oil Consumption (kg/hour) Frequent 13.3 Gas Intake (m3/hour) *** Temperature Level Screen Digital Show Temperature Level Degree Protection…

Read More

Melt blown Production Line 400mm and 1600mm and ES Fiber Production Line and N95 Mask Machine and Disposable Mask Machine

1. N95 and Disposable Mask Machine   2. 400mm and 1600mm Melt blown Production Line 3. ES Fiber Production Line       N95 Face Mask Machine Production Line Melt blown Production Line   A.)Optional Ability: 1600mm Efficiency: 95-97percent FOB Term Cost: USD per pair Price Valid: 5days. Ave.60 Days prepared for shipping. In stock…

Read More

Containerized Mobile Heater Pre-assembled, containerized Kind

Model CA100 Picture Waste Therapy Medical Waste Incineration Treatment Feed Capacity Ordinary 100-200 kgs per feed Burning Price Typical 100-120 kgs per human resources Burning Time per Feed Criterion 1-2 hr Control Placing PLC( Programmable Reasoning Controller Incinerator) Voltage 220V Power 1.0 Kw Gas Diesel oil Burner Italy Heater Feed Mode Handbook Temperature Level Monitor…

Read More

Hiclover waste burner additional components

We are china incinerator manufacturer, contractor and exporter. Manufacturer make reasonable price for incinerator customer, supply medical incinerator, hospital incinerator, animal incinerators, hog incinerators, pet cremation equipment, small incinerator, pet incinerator, animal incinerator, portable incinerator, small animal incinerator, infectious waste pyrolysis machine, laboratory incinerator. HICLOVER help customer reduce purchase budget, custom made function, quality products…

Read More

N95 Face Mask Machine Production Line on Sale Now!$250,000USD per set

N95 Face Mask Machine Production Line on Sale Now! $250,000USD per set N95 Face Mask Machine Production Line on Sale Now! l Dimension(L*W*H): 1037*855*1780 l Power Supply 15.3kw mono phase l Net Weight: approx.: 1500kg HICLOVER – Medical Environmental    WWW.HICLOVER.COM Waste Incinerators Medical Waste Incinerator Pet Animal Cremation Solid Waste Incinerator Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.vip.hiclover.com  Email: [email protected]Email: [email protected]   Nanjing Clover Medical Technology Co.,Ltd.   2020-04-10

Read More

incinerator manufacturer in china

of primary and secondary air? 7. Is it possible to have an automatic bottom ash unloading system? 9. Is it possible to have an automatic bottom ash unloading system? 6. Does it provide for management interventions to correct waste feed, grate speed, and temperature, quantity and supply of primary and secondary air? 5. Does this…

Read More

FFP2 Breathing mask machine

平面口罩机参数: Semi-Automatic Mask Machine l Power supply: 3.3KW mono Stage l Mask Size: 175mm*80-100mm (two or three layers) l Nonwoven (GMS): 10-50g l Capacity: 120 to 150pcs/min l Dimension(L*W*H):3800mm*500mm*1400mm l Net Weight: Approximately 1000kg   焊接机参数: Welding Machine l Capacity: 5 to 10pcs/min l Power supply: 8.5KW mono Stage l Compressed Air connection: 0.5 to 0.7Mpa l Dimension(L*W*H): 900mm*650mm*1380mm l Net weight: approx. 50kg   KN95口罩机参数: N95 Mask Machine…

Read More

Twin heat heaters in addition to Double chamber heater Burning Capacity up to 30 Kg per hr with wet scrubber

Dual heat burners and dual chamber incinerator Burning capacity up to 30 Kg per hour Main Product List Primary Combustion Chamber(Main body stainless steel) Secondary Combustion Chamber(Main body stainless steel) Mix-Combustion Chamber Wet Scrubber( Washing Tower)(Main body stainless steel) Incinerator Control Case Chimney:5.0Meters  Stainless Steel Italy gas burner: 02 sets Oil Tank (if oil fuel):…

Read More

waste incinerator manufacturer in china

Burning rate: 250 Kg/hr. It should be able to Operate not Less than 10 hours/day This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc… Design Specification: Types A, B, C, D, and E of medical waste “PYROLYTIC” combustion, by controlling the gasification of waste. The incinerator…

Read More

Typical 10kgs per hour incinerator for small hospital

This equipment quality structural for kinds of site, like hospital, environmental department,  animal cremation agencies, etc.  HICLOVER Incinerator supply updated models with dual combustion chamber,  mix-combustion chamber and smoke filter  chamber with refractory lines, and the combustion chamber temperature up to 1200 deg C. Equipment Technical Specifications Model YD-10C Picture Feed Capacity Typical 40 kgs…

Read More

Medical Waste Burner Capability Requirement 100kgs per hr

Temperature Level Show & & & & PLC Control Instance Main Burning Chamber Incinerator Text ***Primary Combustion Chamber Italy Oil/Gas Heating Unit ***Chimney:10.0Meters *** 2nd Burning Chamber *** Smoke Filter Chamber ***Italy oil/gas burner: 02 units ***Oil Tank (if oil fuel): 200Liters *** Heater PLC Control Circumstances Items/Model TS100( PLC) Principle Waste Incineration Therapy Melt Cost…

Read More

Containerized Mobile Incinerator Version CA50

Waste Burner (Containerized Mobile Heater) Ability: Normal 50 kgs per human resources Style CA50 Interior Dimensions 100 x 80 x 70 centimeters Main Product Listing Main Burning Chamber Added Burning Chamber Smoke Filter Chamber Heater Control Situation Smokeshaft:5.0 Meters *( upgrade to Stainless-steel, cost-free rate) Italy oil/gas heater: 02 systems Oil Container (if petroleum gasoline…

Read More

Design TS30 oil ended waste tiny burner 30kgs

Model TS30 oil fired waste small incinerator 30kgs/hr. Items/Model TS30( PLC) Picture Melt Price Average 20-30 kg/hour Feed Capacity Regular 60kg per feeding Control Establishing PLC( Programmable Thinking Controller Incinerator) Burning Chamber 330L Inner Measurements 75x75x60cm Secondary Chamber 180L Smoke Filter Chamber Yes Feed Establishing Manual Feeding Voltage 220V Power 0.5 Kw Oil Utilization (kg/hour)…

Read More

50-100-150-200 Kgs per Hour Solid Waste Incinerator Model TS150 PLC 1570Liters Chamber

Waste Incinerator Model TS150 PLC, Overview Construction is dual/double combustion chamber with 02 sets oil burner, batch load  incineration equipment. Waste feed chamber is 1570Liters (1.57m3, TS150 PLC).  Primary & Secondary combustion chambers and smoke filter chamber.  Batch load on the bottom of chamber. Incinerator PLC panel control suit for local operation. Primary Combustion Chamber: …

Read More

Hiclover waste burner

Key Features: — — — — Complete selection burner with Saved money Tiny Scale burner, Standard Small-Large Range heater, General Municipal Solid Waste Heater, Family members Pet dog and likewise Pet Cremation, Containerized Mobile Burner, High Effective Environmental Waste Burner. — Single combustion chamber, double combustion chambers, three combustion chambers and  multi-combustion chambers waste incinerators….

Read More

Medical Incinerators Supplier in China

*** Primary combustion chamber & secondary combustion chamber *** Smoke filter chamber(dry scrubber) *** stainless steel chimney *** PLC auto. control *** Italy made oil or gas burner(diesel oil/natural gas/lpg) *** temperature display and control *** high temperature firebrick,etc Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50…

Read More

hiclover.com macau pet cremation incinerator

Presently, we supply different series for local customer requirements and design  updated incinerator with our leading technology. The updated design feature  of our range of incinerators make them one of the most cost effective in the world. Key Features: * All models with Dual combustion chamber.  * Stainless Steel chimney/stack, long lifetime.  * High temperature, long lifetime of incinerator. * Free or minimum installation on site. * High burn rate, from 10kgs to 600kgs per hour, up to 10ton per day. * PLC Control Plane for Intelligent operation.  * New Design for pet animal cremation business. * One year warranty on incinerator and parts in stock. It features unique and advanced merits with compact size, high burning effect,  reasonable burning technology, high degree of non-harm etc.It is an ideal  choice for waste treatment of hospitals, hotels and various areas. Features: (5)   Compact structure and small land occupation. WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. (1)   Gasifiedpyrolysis incineration is used for burning many Types of waste. Mobile: +86-13813931455(whatsapp/wechat)Website: www.vip.hiclover.com  Email: [email protected]Email: [email protected]   Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg…

Read More

hiclover 10kgs per hour incinerator

Smallest waste incinerator for small hospital  average 10kgs per hour.  with double(2) sets burner. Tools Technical Specifications Version YD-10 Feed Capability Average 20 kgs per feed Burning Cost Regular 10 kgs per hour Burning Time per Feed 2 humans resources Voltage 220V Gas Diesel oil Heater Italy Heater Feed Establishing Guidebook Gas consumption (Oil) 5.4-12.6…

Read More

20-30kgs of waste per human resources with water scrubber

Merchandise Specification Variation YD-30C (client made version) Main Product List Main Burning Chamber( Text stainless-steel) Second Combustion Chamber( Main body stainless steel) Mix-Combustion Chamber Damp Scrubber( Washing Tower)( Text stainless-steel) Incinerator Control Instance Smokeshaft:5.0 Meters *( update to Stainless Steel, cost-free cost) Italy heater: 02 systems Oil Container (if petroleum fuel): 100Liters Style YD-30C Feed…

Read More

3 Chamber Incinerator

Primary chamber:Heavy duty mild steel casing, High quality Refractory lining and insulation 01 x natural gas ignition burners (automatic)  01 x temperature sensor points with complete internal fans.Secondary Chamber:Heavy duty mild steel casing, high quality refractory lining and insulation 01 x natural gas burners (automatic) with complete 01 internal fans. 02 Sec gas residence times.Third Chamber:Heavy duty mild steel casing, high quality refractory lining and insulation 01 x natural gas ignition burners (automatic) with complete internal fans. 02 Sec gas residence time.Integrated dual flu gas washer: Resultant gasses passed through dual gas filtration system for maximum clean emission. It is also equipped with chain filters.Chimney:Heavy duty 5mm or more stainless steel casing mild steel casing.Stack cap/spark arrestors.Control Panel:a.Temperature Monitoring with 4 digit display.b.Thermostat control device for burner (fuel saver)c.Temperature control 0-12 hours.d.Integral fan timer control

Read More

3 Chamber Incinerator

Primary chamber:Heavy duty mild steel casing, High quality Refractory lining and insulation 01 x natural gas ignition burners (automatic)  01 x temperature sensor points with complete internal fans.Secondary Chamber:Heavy duty mild steel casing, high quality refractory lining and insulation 01 x natural gas burners (automatic) with complete 01 internal fans. 02 Sec gas residence times.Third Chamber:Heavy duty mild steel casing, high quality refractory lining and insulation 01 x natural gas ignition burners (automatic) with complete internal fans. 02 Sec gas residence time.Integrated dual flu gas washer: Resultant gasses passed through dual gas filtration system for maximum clean emission. It is also equipped with chain filters.Chimney:Heavy duty 5mm or more stainless steel casing mild steel casing.Stack cap/spark arrestors.Control Panel:a.Temperature Monitoring with 4 digit display.b.Thermostat control device for burner (fuel saver)c.Temperature control 0-12 hours.d.Integral fan timer control

Read More

smart ash incinerator

It is an auto reader for Bacillus Stearothermophilus to test the spore discharge after treatment (sterilization) of (G) Technical Specifications of Spore tester Features and Specifications: should be a very Accurate, reliable and easy-to-use units for reading rapid readout biological indicators (RRBI) for the waste. Automatically reads indicator results. There should be red plus (+)…

Read More

A MOBILE MEDICAL WASTE INCINERATORS

Key Product Checklist Main Burning Chamber Additional Combustion Chamber Mix-Combustion Chamber Smoke Filter Chamber Incinerator Control Circumstance Smokeshaft:5.0 Meters *( update to Stainless Steel, free cost) Italy oil burner: 02 collections Oil Storage Tank: 150Liters Mobile Trailer for Incinerator Version YD-50C Burning Price (kgs/Hour) Average 20-50 kgs/hour Feed Ability (kgs) Typical 80 kgs/feeding Instruments Weight…

Read More

Burner YD-500 for Vietnam

We complete this job in year 2010 to 2011 and distribution to Hochiminh port, Vietnam with 1×× 40′ feet open leading full container. Chimney Type 257x147x108 Primary Chamber (Liters) (adsbygoogle = window.adsbygoogle || []).push({}); 500 kgs/Hr. 1000℃-1200℃ 4000 Residency Time YES Items/Model 800 kgs Medical Environmental  1500 Secondary Chamber (Liters) Oil/Gas 14{ (adsbygoogle = window.adsbygoogle…

Read More

TECHNICAL INCINERATORS SPECIFICATIONS FOR 2 hospitals in Kenya

TECHNICAL INCINERATORS SPECIFICATIONS FOR 2 hospitals   All the incinerators to be supplied and installed must meet the Government of Kenya waste Management Regulation 2006 in particular 3rdschedule regulation (26, 47) pertaining classification, standards, criteria, and procedure for installing/operating incinerators as authored by the National Environmental Management and Coordination (waste management) regulation 2006, legal notice…

Read More

Heater YD-100 for Iraq

There are 03 sets Design YD-100 circulation to Iraq between year 2013 to 2014. The heater use for neighborhood a range of structure in addition to construction sites along with all gas type is diesel oil. Items/Model YD-100 Burning Rate (kgs/Hour) 100 kgs/Hr. Feed Capacity (kgs) 200 kgs Equipment Weight 5300 kgs Primary Chamber (Liters)…

Read More

domestic incinerator

Documents to be submitted as following; Fabricators accreditations Test report to prove ZERO harmful emission level provided as samples form other installations Test report to prove sterility achieved at 6log to 10 level to be provided upon commissioning report and validation.   Technical proposal include: The hospital should provide the necessary space: building & infrastructure,…

Read More

Heater YD-30 for Australia

2nd Chamber (Liters). Items/Model 1000 ℃ -1200 ℃. UNDOUBTEDLY. Mix-Combustion Chamber. 30 kgs/Hr. 200. Outdoors Dimensions (cm). 100x60x60. INDEED. Smoke Filter Chamber. 145x90x175. Inside Measurements (centimeters). Stainless-steel. Additional Chamber. 60 kgs. Tools Weight. Heater Design YD-30 for Australia Melbourne client. 5. Chimney Kind. CERTAINLY. Combustion Fuel. 2.0 Sec. Temperature level Tracking. YES. First. Chmaber Temperature…

Read More

China promises control as Disease Develops

news from: http://www.chinadaily.com.cn/a/202002/01/WS5e347a86a310128217273ead.html  THAT proclaims split constitutes global public wellness emergency China guaranteed on Friday to work with the global community to support regional as well as also global wellness safety, and also repeated it has the positive self-image as well as also capability to win the fight versus the one-of-a-kind coronavirus outbreak, which has in…

Read More

Wuhan virus: China mobilises medical groups to fight new coronavirus

News from: https://www.thestar.com.my/news/nation/2020/01/26/wuhan-virus-china-mobilises-medical-teams-to-fight-new-coronavirus  WUHAN (Bernama): China is mobilising medical staff to aid Wuhan, the centre of the novel coronavirus (2019-nCoV) outbreak, as the country reported 830 confirmed cases of pneumonia, caused by the virus and 25 deaths by the end of Thursday (Jan 23). By Thursday midnight, Hubei Province in central China reported 549 cumulative confirmed…

Read More

medical waste

———————————–   Failure to establish the authenticity of the certificate the bidder is liable to render the bid non-responsive and bidder open to action in the line with applicable regulations and act. Original catalogue must be submitted Original data sheet must be submitted   Solidifier (Fluid waste disposal Product) Particular Features of Solidifier 21b jar…

Read More

50kgs per hour burner with Two chambers vendors from china

50kgs per hour incinerator with two chambers suppliers from china *Aveage 50kgs per hour *Double chamber and double burner *900liters primary combustion chamber *Italy burner *Stainless steel chimney Variation YD-50 Burning Cost Average 50 kgs/hour Feed Ability Typical 150 kgs Primary Burning Chamber 900 Litres Additional Combustion Chamber 300 Litres Mix Burning Chamber Yes Smoke…

Read More

30kgs medical waste heater Design TS30 PLC.

30kgs per hour(average) medical waste incinerator, design dual  combustion chambers(primary chamber and secondary chamber),  smoke filter chamber, PLC auto. control system, 0.33m3(330liters) primary combustion chamber, italy oil or gas fuel burner. for small  hospital medical waste treatment. Buy waste incinerator, find hiclover Items/Model TS30 PLC Idea Waste Incineration Burn Rate Criterion 30kgs/hour Gas Kind Diesel Oil/Natural…

Read More

00 BEDS HOSPITAL INCENERATOR TECHNICAL INFORMATIONS

1) Policy – Waste disposal management shall be taken special note to reduce hospital infection. – Infections wastes shall be managed, stored strictly and burnt by a incinerator located at hospital website.   2) Waste Disposal Plan a)Classification – Medical wastes in hospital are classified as follows;   Infections Waste Specially-controlled waste Organ, needle, etc. Industrial waste…

Read More

small incinerators

The incinerator shall be equipped with water injection nozzle link. If the temperature in the primary chamber should rise too high (normal temperature between 300 and 800? C) during the working time, the automated water injection shall be actuated to decease the temperature.   The incinerator shall have the following features and facilities:-   a-   …

Read More

animal incinerator for sale

The incinerator shall be supplied with a range of interconnecting ductwork between the thermal reactor outlet and the inlet of the chimney. This ductwork will consist of refractory lined tubes and higher temperature resistant tubes made from rolled sheet steel of minimum 3mm thickness, welded along the length.   The standard chimney shall be made…

Read More

incinerator manufacturer

“PYROLYTIC” combustion, by controlling the gasification of waste The incinerator manufacturer must prevent the discharge of black smoke and fine dust, during the loadings. It shall have the ability to reduce the quantity of wastes by 98%. It shall have the ability to hold emission in the second burn with gas residence of not less…

Read More

medical waste furnace

The incinerator to be completely assembled logic and wired function tested in the factory, before dispatch.   –      One high flue gas temperature indicator/alarm to provide an audio/visual warning in case of high flue gas temperatures occurring in two phases:-   First stage audible alarm, second stage incinerator shutdown, with a single voltage free contact…

Read More

hospital incinerator

* Burner with fuel, mono-bloc casting directing type with flat flame, lighting and security of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve. * A regulator with electronic viewing for the temperature of combustion. 23.     The installed incinerator must bear a one year guarantee. 22. Process Filtering system: Scruber to…

Read More

Common 10kgs per human resources burner for small Healthcare facility

This equipment quality structural for kinds of site, like hospital, environmental department,  animal cremation agencies, etc.  HICLOVER Incinerator supply updated models with dual combustion chamber,  mix-combustion chamber and smoke filter  chamber with refractory lines, and the combustion chamber temperature up to 1200 deg C. Tools Technical Specifications Version YD-10C Image Feed Capability Common 40 kgs…

Read More

Family Pet Crematory with Movable system & & & & Auto. Door & & Independent Placement

Incinerator Model A1500, Intro Construction is dual/double combustion chamber with 03 units oil/gas burner,  batch load incineration equipment. Animal feed chamber is 1500Liters (Model: A1500).  Primary & Secondary combustion chambers and included mix-combustion chamber,  smoke filter chamber with firebrick and Refractory Concrete chamber. Batch load on  the bottom of chamber. Incinerator panel control suit for…

Read More

Pet crematorium as high as 200KG/day

Animal Crematory Burner Ability: Regular 80kgs per feeding Thing Spec Design A900 Interior Measurements 120 x 90 x 85 CM Match for Family Pet Feline – – – – yes – Family pet – yes Pig – – small Cow – – no Key Product Checklist Key Burning Chamber Additional Burning Chamber Mix-Combustion Chamber Smoke…

Read More

Burning ability 50kg/hr with damp scrubber with dual released heater

This model is small-scale waste incineration equipment for small waste output.  Construction is dual/double combustion chamber with 02 units oil/gas burner.  Waste feed chamber is around 900Liters (0.9m3, YD-50). Primary & Secondary  combustion chambers and included mix-combustion chamber. Waste load on the  bottom of chamber. Incinerator panel control suit for local operation. Design YD-50 with…

Read More

small scale medical incinerator

include automatic stop/start programmed timer control, flame failure gear and ignition failure gear to close off the fuel supply in case of malfunction. The burners shall be mounted so that waste can’t block the fire ports. —   Blood bags & tubing, gloves, Gowns, curtains, etc.. —   Contaminated packaging: bandage etc Each burner shall be designed…

Read More