Large Size Burning Rate:150-200 kg/hr Solid Waste Equipment Primary and Secondary Combustion Chamber Incinerator

Items/Model TS500(PLC) Picture Principle Waste Incineration Treatment Burn Rate 150-200 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 2700L Internal Dimensions 190x120x120cm Secondary Chamber 1300L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Oil Consumption (kg/hour) Average 28 Gas Consumption (m3/hour) *** Temperature Monitor Digital Display Temperature Protection Yes Oil Tank 1400L Feed…

Read More

Heavy duty firebrick for incinerator chamber

Heavy duty firebrick for incinerator chamber 55% of Al203 65% of Al203 75% of Al203 Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.vip.hiclover.com  Email: [email protected][email protected]   Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto. Combustion Chamber 100L 210L 330L 560L Internal Dimensions 50x50x40cm 65x65x50cm…

Read More

Little Waste Incinerator 30kgs per hour Delivery”

Six Sets Medical Waste Incinerator with 30kgs per hour capacity for Afghanistan. Items/Model TS30(PLC) Burn Rate 30 kg/hour Feed Capacity 60kg Control Mode PLC Combustion Chamber 330L Internal Dimensions 75x75x60cm Secondary Chamber 180L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.5Kw Oil Consumption (kg/hour) 10.2–20 Gas Consumption (m3/hour) 9.8–20 Temperature Monitor Yes…

Read More

STRONG WASTE BURNER

Main room — Consists of a monolithic high grade refractory concrete with high grade insulation backing,. Implementing a refractory hearth or equal for continuous ash removal. Secondary Chamber — Consists of high density, low thermal mass refractory ceramic fiber with an innovative low emissivity protective coating. SOLID WASTE INCINERATOR    Feeding Capacity:    200 to 220 Kg….

Read More

Small Incinerator Yd-50c

Product Description YDC incinerator is latest design for waste treatment, include medical waste, animal cremation and other solid waste. This equipment quality structural for kinds of site, such as hospital, incinerator for animals sale price, incinerator for burning waste, incinerator for cremation china, incinerator for labs, incinerator for laboratory animals, environmental department, animal cremation bureaus,…

Read More

chinese incinerator manufacturers

In a simple design with a metal steel drum electric. including: Ancillaries High temperature painting for several of the incinerator. A combustion chamber with fireplace using a filter to retain ashes; Weight    1850kgs Supply of incinerator model PDR-18 with: ·        Ability 100 kg/hr of waste containing up to 85% moisture ?      With 2 diesel pipelines,…

Read More

small capacity incinerators

7.     A 99.99% destruction and removal efficiency (DRE) for each principal organic hazardous constituent (POHC) in the waste feed where: DRE = [(Win – Wout)/Win]*100 2.     If the minimum combustion temperatures aren’t maintained. Arsenic                                       As Barium                                        Ba 5.     All the emission to the air apart from steam or water vapour has to…

Read More

small home incinerators

Equipment Access Openings: Organize all piping and equipment to allow access to openings without disassembly of piping or equipment. Provide space which permits full opening of all doors, panels, and other access openings.   Operating Space: Do not reduce or alter personnel working spaces shown except with prior approval of Resident Engineer.   Fuel Oil…

Read More

A MOBILE MEDICAL WASTE INCINERATORS

Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber Smoke Filter Chamber Incinerator Control Case Chimney:5.0Meters *(Update to Stainless Steel, free cost) Italy oil burner: 02 sets Oil Tank: 150Liters Mobile Trailer for Incinerator Model YD-50C Burning Rate (kgs/Hour) Typical 20-50 kgs/hour Feed Capacity (kgs) Typical 80 kgs/feeding Equipment Weight 2500 kgs(Incinerator) Primary…

Read More

Double Combustion Chamber Containerized Mobile Incinerator

Double Combustion Chamber Waste Incinerator Mounted in ISO 20′ or 40′ Container before leave Factory. Free Installation The incinerator design with primary combustion chamber, secondary combustion chamber(post combustion) and dry scrubber optional. This layout will reduce black smoke, burn completely and Environmentally Friendly. Mobile Incinerator The incinerator mounted already in the container, complete with fuel…

Read More

Biological and Pathological Waste Incinerator

•Draft Equipment Sulphur Dioxide (SO2): 45 ppmv, 12-hour average as measured by a CEMS; 1Provide a sectional, circular cross section exhaust stack of the kind, size, and number of segments in compliance with the needs of the stack and refractory manufacturer to adequately support the refractory lining, permit growth, and prevent cracking of the refractory;…

Read More

Containerized Mobile Incinerator Medical Waste Incinerator Model CA50

HICLOVER – Containerized Mobile Incinerator Medical Waste Incinerator Model CA50 Model CA50 Picture Waste Treatment Medical Waste Incineration Treatment Feed Capacity Average 100 kgs per feeding Burning Rate Average 50 kgs per hour Burning Time per Feed Average 2 hour Control Mode PLC(Programmable Logic Controller Incinerator) Voltage 220V Power 1.0 Kw Fuel Diesel oil Burner Italy…

Read More

Incinerators QA

Q: what is kind of waste can use in this equipment?A: This equipment for medical waste, pet animal, Municipal waste, live waste. Prohibit any  explosive and radiation material, liquid waste and gas waste. Q: Incinerator Smoke StandardA: China Government Standard: No.GB18484-2001. Q: Treatment capacityA: Average Capacity calculated by medical waste(lower calorific power (L.C.P): 3.0TH Kcal/Kg per hour),  not mean any waste material. The animal/pet combustion rate around 2/3 of average capacity.   Clover incinerator use time per day up to 24 hours. Between each feed/combustion time,  there are about 0.5-1 hours cooling time and time for feeding waste. Actual combustion  time per day is around 16 hours. The lifetime of incinerator between 5-10 year according to use.  Generally, we proposal small laboratory, small clinic use capacity under 20 kgs per hour.  When incinerator use in hospital, please calculate the waste output capacity around 2kgs  per people per day. If there are 200 sickbed in the hospital, that’s mean you need one  incinerator capacity around 400kgs per day, change to capacity per hour is around 30-40 kgs  per hour. According the operation time per day, waste material, budget,  development, etc, you can use capacity from 30-50 kgs per hour incinerator.*How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste. Q: Assembly and TestingA: We supply all documents and incinerators easy to installation and operation. Customer  can send people come to our factory to learn installation and operation. Generally,  We do not send engineer to local site if not request. The dispatch cost is extra according to order. Q: Combustion TemperatureA: The first combustion chamber: 800-1000 centi degree.The second combustion chamber: 1000-1200 centi degree. Q: Incinerator Control ModeA: Default Control mode is common control case. PLC mode according to model and order. Q: Operation and maintenance costsA: Operation cost according to fuel consumption rate and power/staff, etc.  Annual around $500-$1000usd per year maintenance according model, use situation.  One person can service 02 unit incinerators. The staff should have basic electrician  knowledge to operate/inspect/maintaince incinerator/burner/blower according to  operation user guider, and know risk of medical waste to protect worker self with necessary protection element. Q: The Residency time in secondary combustion chamber A: 02 sec. WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.vip.hiclover.com  Email: [email protected][email protected]   Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour…

Read More

Pet Crematory with Movable system & & Automobile. Door & Independent Position

Incinerator Model A1500, Introduction This version is big-scale pet cremation tools for enormous creatures. Construction is dual/double combustion chamber with 03 units oil/gas burner,  batch load incineration equipment. Animal feed chamber is 1500Liters (Model: A1500).  Primary & Secondary combustion chambers and included mix-combustion chamber,  smoke filter chamber with firebrick and Refractory Concrete chamber. Batch load…

Read More

Incinerators QA

Q: what is kind of waste can use in this equipment?A: This equipment for medical waste, pet animal, Municipal waste, live waste. Prohibit any  explosive and radiation material, liquid waste and gas waste. Q: The Residency time in second burning chamber not mean any waste material. The animal/pet combustion rate around 2/3 of average capacity.   Tel: +86 -25 -8461 0201 there are about 0.5-1 hours cooling time and time for feeding waste. Actual combustion  time per day is around 16 hours. The lifetime of incinerator between 5-10 year according to use.  Clover incinerator use time daily to 24 hours.  Between each feed/combustion time,  When incinerator use in hospital, please calculate the waste output capacity around 2kgs  per people per day. If there are 200 sickbed in the hospital, that’s mean you need one  incinerator capacity around 400kgs per day, change to capacity per hour is around 30-40 kgs  per hour. According the operation time per day, waste material, budget,  development, etc, you can use capacity from 30-50 kgs per hour incinerator.*How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste. Generally, we proposition small lab, small clinic use capability under 20 kgs per hour.  can send people come to our factory to learn installation and operation. Generally,  We do not send engineer to local site if not request. The dispatch cost is extra according to order. Q: Assembly and TestingA: We provide all documents and incinerators simple to setup and operation.  Client Q: Combustion TemperatureA: The first combustion chamber: 800-1000 centi degree.The second combustion chamber: 1000-1200 centi level. Q: Incinerator Control ModeA: Default Control mode is common control case.  PLC mode according to order and model. Q: Operation and maintenance costsA: Operation price based on fuel consumption rate and power/staff, etc.  Annual around $500-$1000usd annually care according model, use situation.  knowledge to operate/inspect/maintaince incinerator/burner/blower according to  operation user guider, and know risk of medical waste to protect worker self with necessary protection element. One person can service 02 unit incinerators.  The team should have basic electrician  A: 02 sec. WWW.HICLOVER.COM|Waste…

Read More

Incinerator YD-150 with Stainless Steel Wet scrubber-Cooling Spray tower

Model YD-150 Burning Rate Average 150 kgs/hour Feed Capacity Average 300 kgs/feeding Primary Combustion Chamber 1500 Liters Secondary Combustion Chamber 500 Liters Mix Combustion Chamber Yes Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V/380V Power 1.03Kw Fuel Type Diesel Oil/ Natural Gas/LPG Burner Italy Original Oil Consumption (Diesel Oil) 17–36 kg/hour Gas Consumption (Natural…

Read More

incinerator plant specification

1) Power Supply: ( a) Keys Supply: ( I) Singular Phase supply; 220– – 240V, 50Hz( ii) 3 Stage provide; 380– – 415V, 50Hz( iii) The power supply electrical outlet (sockets) for solitary stage supply system in the hospital is three pins as well as additionally adheres to BS1363. |} (b) Change:-LRB- I) Keys modification…

Read More

Medical Waste Disposal Incinerator, Clover Incinerator

Basic Info. Model NO.:medical waste equipment Export Markets:Global Product Description Nanjing Clover Medical Technology Co., Ltd.  Nanjing Clover Medical Technology Co., Ltd.. Key Features:  * All models with Dual combustion chamber. *according to order  * Stainless Steel chimney/stack, long lifetime. *according to sequence * High temperature, long lifetime of incinerator.  * Free or minimum installation…

Read More

Waste Incinerator Capacity of 10 to 30 Tons / Day

Basic Info. Model NO.:average cost for a medical incinerator Export Markets:Global Product Description Key Features:  * All versions with Dual combustion chamber.  * Stainless Steel chimney/stack, long life. *according to sequence * High fever, long life of incinerator.  * Free or minimal installation on site.  * High burn rate, from 10kgs to 500kgs per hour,…

Read More

3 Combustion Chambers MEDICAL WASTE INCINERATOR

Version WS-35 Photo Burning Price Average 35 kgs/hour Feed Capacity Average 80 kgs Main Combustion Chamber 460 Liters Secondary Combustion Chamber 200 Litres 3rd Burning Chamber 200 Litres Smoke Filter Chamber Wet Scrubber System Feed Mode Manual Voltage 220V Power 2Kw Gas Type All-natural Gas/LPG Heater Italy Original Oil Consumption (Diesel Oil) *** Gas Consumption…

Read More

installation of waste disposable incinerator system

installation of waste disposable system in airport.Incinerator with oil burner –          The layout should prevent any discharge of polluting substances into soil, surface water and groundwater. –          Combustion zone has to reach at least 860 degrees under the most adverse conditions with at least 6% oxygen. Since it will treat hazardous and organic waste, temperature…

Read More

100-150kgs Burning cost with Secondly burning to be usage in the Gym

Oil tank with 2000Liters capacity Items/Model TS150( PLC) Image Principle Waste Incineration Therapy Burn Rate Requirement 100-150 kg/hour Feed Ability Standard 750kg/feeding Control Setting PLC( Programmable Thinking Controller Burner) Text Steel 8mm thickness Chamber Product High Alumina Fire Brick Wall Surface, 1750 ℃ Rate Paint for outside face 800 ° C Rate Combustion Chamber 1570L…

Read More

Garbage Incinerator TS150 PLC Mobile Type

Items/Model HICLOVER TS150(PLC) (Mobile Type) N1155 Picture  mobile incinerator Principle Waste Incineration Treatment,trash incinerator Burn Rate Average 150 kg/hour Feed Capacity Average 150kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1200L Internal Dimensions 120x100x100cm Secondary Chamber 600L Smoke Filter Chamber Yes(Dry Scrubber) Feed Mode Manual Voltage 220V Power 0.9Kw Oil Consumption (kg/hour) Typical 20.4 Gas Consumption (m3/hour)…

Read More

Likewise biomedical and harmful waste

is instilled and also full burning is reached. Solitary Chamber Excess Greater than an adequate amount of air (as high as 50% more than the amount On the surface supplied gas in addition to power are needed for the heaters along with forced air ventilation. A correctly running double- room controlled air system will definitely…

Read More

china medical waste incinerator

Incinerate: medical waste and general waste Capacity to burn waste: 400 — 500 kg/hr Fuel: Diesel Fuel Consumption: 10 litres/hr maximum Incineration temperature: 950 – 1300 °c Casing: thick (min 5 mm) Stainless steel casing and completely insulated to withstand sea humidity Voltage: 220/240 V or 380/415V Frequency: 50 Hz Feeding: automatic Ash 1 leftovers…

Read More

Incinerator factory

Key Features: General Municipal Solid Waste Incinerator, Pet and Animal Cremation,  Containerized Mobile Incinerator, High Efficient Environmental Waste Incinerator.— Single combustion chamber, double combustion chambers, three combustion chambers and  multi-combustion chambers waste incinerators.— System solutions for medical waste environmental.— High burn rate, from 5kgs to 1000kgs per hour.— New Design for pet animal cremation business. — HICLOVER, trusted partner with years of experience. WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. — Full range incinerator with Economized Small Scale incinerator, Standard Small-Large Scale incinerator,  Mobile: +86-13813931455(whatsapp/wechat)Website: www.vip.hiclover.com  Email: [email protected]Email: [email protected]   Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg Control Mode PLC PLC PLC PLC PLC Combustion Chamber 100L 210L 330L 560L…

Read More

waste disposal burner

Incinerator but the dimension of chamber > 2000 x >> 1200 mm. Prepare for melt FLUID Waste +/- 20 liter/hr. The chamber of the incinerator should be able to hold about 200 – – 250 kg of waste in an offered time. edical Waste Incinerators. The mobile system is our concern then the fixed systems….

Read More

Cost to Buy a Medical Waste Incinerator

Basic Info. Model NO.:cremation equipment for sale in china Export Markets:Global Product Description Nanjing Clover Medical Technology Co., Ltd.. Key Features:  * All models with Dual combustion chamber.  * Stainless Steel chimney/stack, long lifetime. *according to order  * High temperature, long life of incinerator.  * Free or minimal installation on site.  * PLC Control Plane….

Read More

medical waste incinerators china

Ensure flame contact with all gases is achieved. –yes Ensure residence time is not less than two (2) seconds. –yes Ensure the gas temperature as measured against the inside wall in the secondary chamber & not in the flame zone, is less than 1100oC. –1000-1200 oC   Ensure the oxygen content of the emitted gases…

Read More

50kgs per hour burner with Two chambers vendors from china

50kgs per hour incinerator with two chambers suppliers from china *Aveage 50kgs per hour *Double chamber and double burner *900liters primary combustion chamber *Italy burner *Stainless steel chimney Variation YD-50 Burning Cost Average 50 kgs/hour Feed Ability Typical 150 kgs Primary Burning Chamber 900 Litres Additional Combustion Chamber 300 Litres Mix Burning Chamber Yes Smoke…

Read More

large animal incinerators

The incinerator shall also be equipped with special loading apparatus and mechanisms that allow safe incineration of solid waste simultaneously with liquid sludge. Loading of solid waste could be achieved through bags.   All intermediate piping, bellows and other fittings for connection between the tanks , burner, compressor and other equipment provided on the slide…

Read More

animal incinerator for sale

The incinerator shall be supplied with a range of interconnecting ductwork between the thermal reactor outlet and the inlet of the chimney. This ductwork will consist of refractory lined tubes and higher temperature resistant tubes made from rolled sheet steel of minimum 3mm thickness, welded along the length.   The standard chimney shall be made…

Read More

Infectious Waste Incinerator

Product Description Principle of the Incinerator Gear is incineration/combustion/burn. The main body is one combustion chamber (at least), Refractory line or firebrick, Insulation materials and the outer plate. Ignition element is outside gas or oil burner. The burner may be operating until waste burnout but for some waste like plastic, newspaper (sometime, mix coal with…

Read More

Containerized Mobile Incinerator Pre-assembled, containerized type

Model CA100 Picture Waste Treatment Medical Waste Incineration Treatment Feed Capacity Average 100-200 kgs per feed Burning Rate Average 100-120 kgs per hour Burning Time per Feed Average 1-2 hour Control Mode PLC(Programmable Logic Controller Incinerator) Voltage 220V Power 1.0Kw Fuel Diesel oil Burner Italy Burner Feed Mode Manual Temperature Monitor Digital Display Fuel consumption…

Read More

Small Medical Waste Incinerator 2 combustion chambers with scrubber

Small Medical Waste Incinerator 2 combustion chamber with scrubber for Virus medical waste On-Site Incineration Solution‎ Medical waste incineration involves the burning of wastes produced by hospitals, veterinary facilities,  and medical research facilities. These wastes include both infectious (“red bag”)  medical wastes as well as non-infectious, general housekeeping wastes. Items/Model TS30(PLC) Picture   Burn Rate…

Read More

hiclover waste incinerator spare parts

We are china incinerator manufacturer, contractor and exporter. Manufacturer make reasonable price for incinerator customer, supply medical incinerator, hospital incinerator, animal incinerators, hog incinerators, pet cremation equipment, small incinerator, pet incinerator, animal incinerator, portable incinerator, small animal incinerator, infectious waste pyrolysis machine, laboratory incinerator. HICLOVER help customer reduce purchase budget, custom made function, quality products…

Read More

Small Hospital Incinerators

Basic Info. Export Markets:Global Additional Info. Trademark:clover Origin:Nanjing Clover Product Description Nanjing Clover Medical Technology Co., Ltd.. The TS PLC model incinerator come rather than SYC model now. SYC model incinerator included model SYC-10/20/30/50/100 and these model stop supply for market. We provide updated TS PLC versions, more function, PLC control, stainless steel chimney and…

Read More

Incinerator A4000

Basic Info. Model NO.:A4000 Pullution Sources:Solid Waste Processing Processing Methods:Combustion Export Markets:Global Additional Info. Trademark:CLOVER Product Description Nanjing Clover Medical Technology Co., Ltd.. Items/Model A1500 A2400 A4000 A5500 Burning Rate *animal 90 kgs/Hr. 150 kgs/Hr. 200 kgs/Hr. 400 kgs/Hr. Feed Capacity *animal 120 kgs 200 kgs 300 kgs 500 kgs Equipment Weight 7000 kgs 8300…

Read More

Medical Waste Incineration Model TS20(PLC) Wet Scrubber (Water Spary tower)

Phone: +86-13813931455(whatsapp/wechat)Website: http://www.vip.hiclover.com/  Email: [email protected]Email: [email protected]   Nanjing Clover Medical Technology Co.,Ltd. Items/Model TS20(PLC) Picture   Principle Medical Waste Incineration  Burn Rate Average 20 kg/hour Feed Capacity Average 40kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 210L Internal Dimensions 65x65x50cm Secondary Chamber 110L Smoke Filter Wet Scrubber (Water Spary tower) Feed Mode Manual Voltage 380V Power 5Kw Oil Consumption (kg/hour) 7.8–16.3 Gas Consumption…

Read More

Waste Incineration Treatment BURNING COST: 100-150kgs per Individual resources HICLOVER TS150

BURNING RATE: -100 -150 kgs per hr MINIMUM OPERATING TEMPERATURE: 800-1000 oC (PRIMARY BURNING) MAX OPERATING TEMPERATURE LEVEL LEVEL: 1000-1200 oC (AFTER HEATING UNIT BURNING) SECONDARY MELTING ABILITY: COMPULSORY THICKNESS INSULATION: 50 mm top Refractory ability: mins 114mm STURDY REFRACTING LINING TO WITHSATND 17500C AVEARGE WEAR OUT TIME: MAXIMUM 3HRS GAS KIND: GAS OIL (DIESEL)…

Read More

an animal cremator

2 Power Supply Summary 1{ (adsbygoogle = window.adsbygoogle || []).push({});|} Non Corrosive/ Rust Resistant Ideally Stainless for longer Life (Elevation 5-7 Meter) 7 Smokeshaft Product Dual Burning Chamber with Integrated In Smoke Filter (Dry Scrubber) 6 11 50 Kg. 220/380 Volt A/c 50 Hz. 10 Gas Burning Chamber Requirement PLC Control Panel 9 Control board…

Read More

laboratory incinerator

the Whole carcass of animals ( Horses, Cows, Incinerators should be provided in the fuel tank (diesel ) The destruction of 1000 kg / hour. Incinerator capacity is calculated ? must have fuel with automatic control and malfunction So as to get the proper effect. Consistency is independent of the initial and secondary chambers. Must…

Read More

smart ash incinerator price

Flue Gas Cleaning   System   ?   quoted individually )     7 Chimney Height 10m (minimal )       ?     Overall duration of the supervision of installation, testing and commissioning works shall not exceed 2 weeks.     2.11       Commissioning     Commissioning  tests  to  be  performed on  site  shall  include  but …

Read More